Accu-Scope Microscope Warranty
 
Accu-Scope Biological MicroscopeAccu-Scope Compound MicroscopeAccu-Scope Digital MicroscopeAccu-Scope Metallurgical MicroscopeAccu-Scope Inverted MicroscopeAccu-Scope Stereo MicroscopeAccu-Scope Gemological MicroscopeAccu-Scope Educational MicroscopeAccu-Scope Student MicroscopeAccu-Scope Inspection MicroscopeAccu-Scope Microscope CamerasAccu-Scope Microscope IlluminationAccu-Scope Microscope ObjectivesAccu-Scope Microscope EyepiecesAccu-Scope Microscope Everything ElseAccu-Scope Microscope WarrantyHow To Order Microscopes and Microscope AccessoriesAccu-Scope Microscope Site MapView Your CartAccu-Scope Microscope Contact Us

Accu-Scope's products are backed by an industry leading five-year limited warranty for parts, labor and electronic components.

While many companies talk about quality and value, these ideals are the foundation on which Accu-Scope's company has been built for over 60 years. From personal inspections and audits of the factories that build Accu-Scope's products, to the individual testing of each microscope at Accu-Scope's New York facility, to the endless parts support Accu-Scope offers, Accu-Scope provides a level of quality and value that is unsurpassed in the marketplace.

Accu-Scope's knowledgeable staff is qualified and willing to assist you in your selection and purchase of a microscope. Accu-Scope offers the only 5 year electrical warranty in the industry and can still repair/replace microscopes we manufactured as far back as the early 1960’s. 

MICROSCOPE CLEANING INSTRUCTIONS:
LENS SHOULD BE INSPECTED FOR DUST, DIRT OR OIL PRIOR TO CLEANING 
DO NOT CLEAN OPTICAL SURFACES UNLESS  DUST, DEBRIS OR OIL IS AFFECTING OPTICAL PERFORMANCE 
CLEANING SHOULD BE ATTEMPTED ONLY IF THERE IS CLOUDINESS, POOR DEFINITION OR POOR CONTRAST 
 

CAUTIONS

Use care not to grind microscopic dirt into the soft glass of an objective. Doing this will scratch the glass. 
Do not apply excessive amounts of solvent to the glass surface. Too much solvent will seep into the lens elements and cause weakening of the cement between elements or coatings. 
Do not use caustic agents as they will remove lens coatings. 
 

CLEANING MATERIALS

The following materials are acceptable by most microscope and optical suppliers:

Lint-free cotton (artificial preferred) swabs on wooden sticks 
Reagent grade acetone or reagent grade isopropyl alcohol 
Compressed air with nitrogen propellant only and/or bellows brush 
 

LENS CLEANING INSTRUCTIONS

Using nitrogen propelled compressed air or a bellows brush, gently remove dust or dirt particles from the lens surface 
Dip the end of a lint-free cotton swab into your solvent 
Shake the swab to remove excess solvent 
Beginning at the center of the lens and using a circular motion towards the outer edges, gently wipe the surface with the moistened end of the cotton swab 
Use nitrogen-free compressed air or a bellows brush to remove any residue 
With a jewelers loupe, inspect the lens for any area not completely cleaned 
If not clean, use new lint-free swabs and repeat cleaning procedure 
 

IF THE LENS IS STILL NOT CLEAN, CONTACT A QUALIFIED PROFESSIONAL SERVICE PERSON TO INSPECT OR REPLACE THE OPTIC

 

MICROSCOPE STAND AND STAGE PLATE CLEANING

Unplug all electrical connections before cleaning. Cleanse the microscope stand and stage surfaces with a lint free soft cloth moistened with a diluted mild soapy solution.  For stereo microscopes remove the stage plate from the microscope stand when attempting to clean.  Do not use a wet cloth to clean the stage. Do not use acetone, alcohol or other solvents as they may damage painted surfaces. Allow the stage plate to thoroughly dry before reattaching to microscope.