Accu-Scope's
products are backed by an industry leading five-year limited warranty for
parts, labor and electronic components.
While many companies talk
about quality and value, these ideals are the foundation on which Accu-Scope's
company has been built for over 60 years. From personal inspections and
audits of the factories that build Accu-Scope's products, to the individual
testing of each microscope at Accu-Scope's New York facility, to the endless
parts support Accu-Scope offers, Accu-Scope provides a level of quality
and value that is unsurpassed in the marketplace.
Accu-Scope's knowledgeable
staff is qualified and willing to assist you in your selection and purchase
of a microscope. Accu-Scope offers the only 5 year electrical warranty
in the industry and can still repair/replace microscopes we manufactured
as far back as the early 1960’s.
MICROSCOPE CLEANING INSTRUCTIONS:
LENS SHOULD BE INSPECTED
FOR DUST, DIRT OR OIL PRIOR TO CLEANING
DO NOT CLEAN OPTICAL SURFACES
UNLESS DUST, DEBRIS OR OIL IS AFFECTING OPTICAL PERFORMANCE
CLEANING SHOULD BE ATTEMPTED
ONLY IF THERE IS CLOUDINESS, POOR DEFINITION OR POOR CONTRAST
CAUTIONS
Use care not to grind microscopic
dirt into the soft glass of an objective. Doing this will scratch the glass.
Do not apply excessive amounts
of solvent to the glass surface. Too much solvent will seep into the lens
elements and cause weakening of the cement between elements or coatings.
Do not use caustic agents
as they will remove lens coatings.
CLEANING MATERIALS
The following materials are
acceptable by most microscope and optical suppliers:
Lint-free cotton (artificial
preferred) swabs on wooden sticks
Reagent grade acetone or
reagent grade isopropyl alcohol
Compressed air with nitrogen
propellant only and/or bellows brush
LENS CLEANING INSTRUCTIONS
Using nitrogen propelled
compressed air or a bellows brush, gently remove dust or dirt particles
from the lens surface
Dip the end of a lint-free
cotton swab into your solvent
Shake the swab to remove
excess solvent
Beginning at the center
of the lens and using a circular motion towards the outer edges, gently
wipe the surface with the moistened end of the cotton swab
Use nitrogen-free compressed
air or a bellows brush to remove any residue
With a jewelers loupe, inspect
the lens for any area not completely cleaned
If not clean, use new lint-free
swabs and repeat cleaning procedure
IF THE LENS IS STILL NOT
CLEAN, CONTACT A QUALIFIED PROFESSIONAL SERVICE PERSON TO INSPECT OR REPLACE
THE OPTIC
MICROSCOPE STAND AND STAGE
PLATE CLEANING
Unplug all electrical connections
before cleaning. Cleanse the microscope stand and stage surfaces with a
lint free soft cloth moistened with a diluted mild soapy solution.
For stereo microscopes remove the stage plate from the microscope stand
when attempting to clean. Do not use a wet cloth to clean the stage.
Do not use acetone, alcohol or other solvents as they may damage painted
surfaces. Allow the stage plate to thoroughly dry before reattaching to
microscope.